Nanobubbles to the rescue
Peter McMaugh shares the Nanobubbles Ltd. New Injectors Test Report and how Nanobubbles can lead the way in wastewater treatment
It is very well known that most governments in Australia don’t want to talk about recycled water. This is just a head in the sand attitude. It is inevitable that it has to happen in every major city and Nano bubble technology can do it very effectively and very cheaply.
The technology can use any gas in any liquid. It is not new technology. It has been around for at least 80 years. Japan has been the leader. The major reason it has not seen its potential is that the generators to date have only been able to generate low volumes of genuine Nano bubbles. An Australian inventor has raised the stakes in this with a new device using titanium.
This means that it can be easily scaled up to deal with issues like the Macquarie Harbour pollution problem. I have been working on using it on turf farms to overcome the low oxygen levels in soils because of compaction.
The NSW TGA received a grant from the Resilience Funds after the 2019-22 floods in the Hawkesbury. It has been used through UNSW. After the glasshouse phase, which has been very promising, we are now entering the field trial work.
The overall science of this technology is applicable across a multiple of areas. It is mind blowing in potential. It is the most exciting technology I have ever worked with.
Nanobubbles Ltd. New Injectors Test Report
This document describes the new Nanobubbles injectors that are securely assembled with clamping force instead of welding (i.e., previously used for securing the membranes inside the injector).
Two new nanobubble injectors were tested:
- 3 Stainless Steel Membranes (described as New-SS Membranes)
- 3 Titanium Membranes (described as New-T Membranes)
These new injectors were compared with the previously owned 3-membrane welded injector.
The tests conducted are:
- Dissolved oxygen rate test
- Mass transfer coefficient test
- Nanobubbles Size Distribution and Concentration

The setup used is shown in Figure 1, which consists of the gas supply (i.e., oxygen), pressure controller, mass flow controller, flow meter, pressure gauge, and pump. The liquid and gas flowrates were set at 2500 L/h and 4 L/min, respectively, with a gas absolute pressure of 5 bars. The operating temperature was controlled using a heat exchanger (KR-SOA Immersion Chiller, PolyScience Temperature Control Solutions, Illinois, USA) to keep the water temperature at ambient conditions. This process recirculates the water across the injector for 30 minutes to ensure a large number of nanobubbles in the water and the dissolved oxygen levels reach saturation.
1. Dissolved Oxygen Rate Test

The dissolved oxygen (DO) rate test was conducted by measuring the dissolved oxygen level of water starting with no DO (i.e., 0 mg/L) while injecting oxygen gas (Oxygen 2.5 supplied from BOC) through the injector. A DO probe (HH306A, OMEGA Engineering Inc., Australia) with a resolution of 0.01 mg/L was used. Figure 2 presents the dissolved oxygen rate versus operational time for the three tested injectors. It is clearly shown that the new injectors provide a similar DO supply compared to the old injector. The new stainless steel and titanium membrane injectors supply a constant rate of DO reaching saturation at ~27 mg/Lat 3:55 minutes and 3:46 minutes, respectively, while the old injector takes 4:25 minutes for the DO to reach saturation at ~28 mg/L. Note that the difference in DO saturation level across the three injectors is due to the variation in the water temperature across the experiment and not due to the injector design.
2. Mass Transfer Coefficient
The volumetric oxygen mass transfer coefficient (K_L a) is the parameter that controls the rate at which oxygen transitions from the gas phase into the liquid phase (i.e., dissolved oxygen). In other words, this coefficient shows numerically how efficiently the injectors convert gaseous oxygen into dissolved oxygen (i.e., a higher mass transfer coefficient indicates a higher efficiency).
The static gassing-out method, a precise and reliable technique, was employed to experimentally measure the mass transfer coefficient. This involved introducing Nitrogen to deplete the oxygen level in the water to O mg/L, followed by the controlled supply of oxygen into the water at a constant flowrate. The subsequent monitoring of the increase in the dissolved oxygen level allowed for an accurate description of the mass transfer coefficient.

Figure 3 shows the mass transfer coefficient for the 3 tested injectors. It is clearly shown that the new titanium-membrane injector has the highest mass transfer coefficient (~6.23 min-1) with an R2 value of 0.87 (i.e., an accuracy estimate) more than double of the old injector. The new stainless steel membrane injector has a mass transfer coefficient of ~3.36 min-1 with an R2 of 0.87 compared to the old injector with a mass transfer coefficient of ~2.63 min-1 with an R2 of 0.68 (i.e., a ~28% higher). This indicates that the new titanium membranes provide a better medium for converting gaseous oxygen to dissolved oxygen.
3. Nanobubbles Size Distribution and Concentration

The bubble size distribution and concentration were measured using the NanoSight NS300 (Malvern Pananalytical), which uses a nanoparticle tracking analysis. This non-invasive technique employs both the Brownian motion and light scattering to provide size distribution of dispersions in a liquid sample. Furthermore, a freeze and thaw method was used to eliminate the bubbles and measure the nanoparticle pollutants to have a more accurate measurement of the nanobubble size distribution. This was done by first measuring the sample’s (i.e., including nanobubbles and other entities in suspension) size distribution before freezing the sample to -15°C for 3 days. The sample was then subsequently thawed at room temperature for at least 1 day before remeasuring the size distribution, showing the data for only the other entities in suspension. Using statical analysis, the difference between both size distributions is the nanobubble data, including the median, mode, and mean bubble diameters, as well as the different size percentiles and the average concentration. The nanobubble size distribution and concentration for each injector are shown in Figure 4 and Table 1.

All three injectors have a similar nanobubble size distribution with a different concentration range. The old injector was found to make a total of 218 million bubbles/ml with a 90th percentile at 239 nm (meaning 90% of bubbles were 239 nm or smaller) with the most frequent size (mode) at 125 nm, average size at 141 nm, and the median at 120 nm (meaning 50% of bubbles were 120 nm or smaller).
The new SS-membrane injector was found to make a total of 1900 million bubbles/ml with a 90th percentile at 176 nm (meaning 90% of bubbles were 176 nm or smaller) with the most frequent size (mode) at 125 nm, average size at 140 nm, and the median at 124 nm (meaning 50% of bubbles were 124 nm or smaller). Finally, the new T-membrane injector was found to make a total of 1130 million bubbles/ml with a 90th percentile at 164 nm (meaning 90% of bubbles were 164 nm or smaller) with the most frequent size (mode) at 75 nm, average size at 124 nm, and the median at 106 nm (meaning 50% of bubbles were 106 nm or smaller).