Self-priming pumps – Where would we be without them?

In this feature, Warwick Lorenz, Managing Director of Aussie Pumps, and Chief Engineer John Hales share their journey, revealing the wins, setbacks, and determination driving their mission to create Australia’s most extensive range of self-priming centrifugal pumps.
Ever been in or around a bushfire? It’s scary! You’ll see people taking outrageously courageous actions, often without thinking, and relying on a Honda petrol-engine-driven self-priming fire pump to do the job.
Anybody who’s been in regional Australia understands that every farmer has got one, two, maybe even three, self-priming centrifugal pumps. Some of them are in the shed waiting to be put back together or just serviced before the next fire or farm job.
In this article, we have put together some of the things that drive people crazy about self-priming centrifugal pumps. For example, the engine not starting when a bushfire threatens… even worse, not being able to pump water when farmers are in the middle of a drought.
Here, we detail some of the most common issues and their simple solutions.
PUMP MECHANICAL SEAL LEAKS
One of the things we like about self-priming centrifugal pumps with petrol engine drive is their simplicity. If the seal starts to leak, you know it’s not because the seal is faulty. Mechanical seal failure occurs when the seal faces, one stationary, one rotating, no longer maintain a tight seal. That allows fluid to leak. Seal failure can manifest as external leaks, reduce the pressure, or, in extreme cases, seal face fusing (adhesion). That will prevent pump operation anytime.
So, let’s deal with seal failures.
CAUSES OF SEAL FAILURE IN SELF-PRIMING PUMPS
DRY RUNNING OR LACK OF LUBRICATION: Mechanical seals rely on a thin film of liquid (the pump fluid or an external flush) to lubricate and cool the seal faces. Running a fire pump dry can cause overheating, leading to seal-face cracking, wear, or fusing.
“It’s easy to see the cause when you pull the seal apart,” says Mr Hales. “It’s simple, the elastomers have melted. Running your pump dry, and the seal failing is not a warranty!” he adds
PUMP CAVITATION: Cavitation creates shock waves from collapsing vapour bubbles, which cause vibration and pressure fluctuations that stress the seal faces. This can lead to pitting, wear, misalignment or accelerated seal failure. An example would be a self-priming pump with insufficient NPSH. For example, high suction lift, cavitation, and vibrating the seal, causing premature wear.
HYDRAULIC SHOCK (WATER HAMMER): The cause is pressure surges from sudden flow changes. For example, rapid valve closure or pump stops. This can misalign or overstress the seal faces, causing leaks or fusing.
Vibrations from shock also wear the seat. An example is a pump abruptly stopping with a long discharge line, creating a pressure surge that damages the seal face.
Solutions to overcome hydraulic shock include avoiding sudden starts and stops, maintaining the check valve and installing slow-closing valves, globav gate with multiple turns.
ABRASION OR CORROSIVE LIQUIDS: Selecting the right pump to handle fluids such as fertilisers, saltwater, or chemicals is imperative. One reason Australian Pumps is focused on 316 stainless steel self-priming centrifugal pumps is that they can also be engine-driven. It’s all about preventing abrasive particles like sand from eroding seal faces. Corrosive liquids, such as acids, can degrade seal material if they are incompatible. This will lead to pitting or cracking.
IMPROPER PRIMING OR AIR INGRESS: Incomplete priming or air leaks in the suction line introduce air into the pump. This will reduce lubrication, leading to dry running or cavitation. Air can also cause seal faces to overheat or stick together during shutdown periods.
There are plenty of people out there who’ve been working with pumps all their lives and still haven’t really understood how to read a performance curve. It’s not anything to do with their intelligence, but rather simply an omission in which everybody assumes they know how to carry out what can be an elementary task.
Here are the first steps.
- The Litres Per Minute (LPM) represents the volume of fluid that the pump can deliver per unit of time.
- The Total Dynamic Head (TDH) in metres is the total equivalent height that the pump can lift fluid, accounting for elevation, friction losses and pressure. An example would be using a self-priming fertiliser pump to handle 100 litres per minute to a maximum head of 36 metres.
The primary curve on the chart you are looking at shows the relationship between flow rate and TDH. It typically slopes downwards from left to right, indicating the flow rate (the flow rate increasing and the pump’s ability to generate head decreasing).
Using an Aussie Fire Chief as an example, the pump volume at zero head could be around 500 litres per minute, whilst in a twin-impeller pump, the maximum head would be around 90 metres.
SELF PRIMING PUMPS NOT PRIMING
The Aussie Pump product range primarily comprises self-priming centrifugal pumps. The self-priming function can run into trouble if the pump is not installed correctly. Common reasons for self-priming pumps not priming can be as follows:
- Air entering the suction line prevents the pump from creating a vacuum to draw liquid. Common issues include loose fittings, cracked hoses or worn gaskets.
- Self-priming pumps require liquid in the casing to initiate priming. If the casing is dry, or has insufficient liquid, the pump cannot create the right suction. If in doubt, move to troubleshooting. Fill the pump body before starting, ensure the check valve (located in the suction port) is working effectively.
- Measure the vertical distance from the liquid surface to the pump’s inlet. Compare it to the pump’s specification.
- Check for friction losses in the suction line. Long hoses or poor fittings will reduce the lift.
- Fluid’s viscosity or temperature can reduce priming ability. Ie. Thick chemicals or sludge.
PUMP INTERNALS DAMAGED
A worn impeller or damaged volute can reduce the pump’s ability to create suction. Pumps can be damaged in the pump chamber when handling abrasive fluids and slurries over time.
If the pump is damaged, replace the impeller and volute to restore the pump’s capability.
GENERAL TIPS FOR TROUBLESHOOTING
- Consult the manual
- Start with simple checks beginning with air leaks and priming liquid.
- Test after each fix, run the pump and isolate the problem.
- Flush with clean water to prevent residual building that may affect priming or seal.
All of the above is based on Australian Pump’s 34 years in business, serving Australia’s agricultural and industrial markets. Focusing on self-priming centrifugal pumps enabled Australian Pump to focus on providing a wide range of pumps for applications as diverse as flood mitigation, firefighting, and even spray irrigation.
Aussie’s range of self-priming pumps varies from 1” x 1” Ultralites to super heavy-duty 6” trash pumps, capable of pumping up to 6,000 litres per minute. The most recent introduction to the market is a complete range of 316 stainless steel self-priming centrifugal pumps for a wide range of applications, including marine, corrosive liquid (fertiliser) and aggressive liquids in mining or process applications.
Australian Pump is proud of its wide range of products that are suited to Australian conditions. Their products are built based on continuous product development with the end user in mind. It should be noted that Australian Pump and its dealer network across Australia and the South Pacific is dedicated to improving pumps with solutions for drought, flood or bushfires.
The company continues to push for water security for Regional Australia. We all should be passionate about that in today’s world of droughts and floods.